Dimplex M Flex Air Installation And Operating Instruction page 28

Domestic ventilation unit
Hide thumbs Also See for M Flex Air:
Table of Contents

Advertisement

English
8.4.4 Service menu 30 – Parameter
31Parameter save
Saves the currently programmed volume flows or all settings
for the digital inputs and outputs.
HINWEIS
NOTE
Particularly before changing the parameters for the digital in-
puts and outputs, it is advisable to save the currently config-
ured parameter settings.
32Parameter load
Loads / restores the settings for the volume flows or the digital
inputs and outputs saved in the Save parameters menu.
33 Parameter restore
Resets the parameters for the volume flows or the digital inputs
and outputs to the factory setting.
34Unit config.
Loads the basic configuration for the relevant unit model. To do
this, the 4-digit UV code must be entered. This can be found on
the type plate of the ventilation unit.
The basic configuration configures the fans and sets the pa-
rameters for the internal and external device components.
1s
1s
1s
1s
Saves all entries in the
Saves all entries in the
"Air flow" menu
Inputs + Outputs menu
1s
1s
Enter UV-Code
typeplate
Fig. 8.9:Service menu 30: Parameter
26
HINWEIS
NOTE
The unit configuration is factory preset when the ventilation
unit is delivered.
The UV code must be entered after replacing the mother-
board for a replacement board. The unit cannot be operated
without the basic configuration.
Sets the ventilation unit to the factory settings. The UV code
must be entered to restart the software (see Unit configuration).
All parameters and individual settings are reset, any program-
ming and the fault memory are deleted.
Up to 8 errors that have occurred are saved in the user menu
under Information / Error signals. All saved error messages are
deleted in the Error memory menu.
The built-in fans communicate with the control PCB via Mod-
bus RS 485. The required configuration is loaded in the factory.
If a fan is replaced, the configuration has to be reloaded. To do
this, go to 30 Service menu - 37 Fan config. First select step
373 - "Factory set. - Start" then step 372 "Configuration - Start"
and then step 371 "Addressing - Start".
1s
1s
1s
Loads all entries in the
Loads all entries in the
"Air flow" menu
"Inputs" + "Outputs"
menu
1s
1s
DOK4SVxxDEN · FD 9912
Domestic ventilation unit M Flex Air (Plus)
35Factory set.
36Error memory
37Fan config.
1s
1s
Loads the factory
settings in the
"Air flow" menu
1s
1s
Deletes all error signals
1s
Lädt alle Eingaben im
Menü „Eingänge" +
„Ausgänge"
1s
1s
1s
www.glendimplex.de