Samsung iDCS 500 Technical Manual page 76

Hide thumbs Also See for iDCS 500:
Table of Contents

Advertisement

iDCS 500 Release 2 / OfficeServ
TECHNICAL MANUAL
There is no special programming required for OPX use; however, it is suggested that
the OPX ports are set for CO ring in MMC 208. The telephone company service facility
interface code for OPX circuits is OL13C.
5.7 T1 CIRCUIT
Using a standard, straight through eight conductor data cable or straight through eight
conductor line cord to connect the customer provided Channel Service Unit (CSU) to
the TEPRI card as shown in
NOTES:
1. It may be necessary to cut off the CSU end of the cable and attach a different
connector to match that of the CSU. If possible, this connection should be soldered
because good connections are critical.
2. It is recommended that the CSU be connected to the network interface with a cable
supplied by the CSU manufacturer. If this is not possible or practical, a custom
cable has to be made up. This cable should be made from 22 gauge two pair cable
with each pair individually shielded. It is recommended that the connections on this
cable be soldered wherever possible to ensure good connections. The shielding of
the cable should be connected to ground at the CSU end only to prevent a ground
loop.
ORDERING A T1
The following information may be useful when ordering T1 service from the telephone
company.
PARAMETER
Framing type
Coding type
The coding type must be set up in the system to match the T1 span and is contained in
MMC 808.
5.8 BRI CIRCUIT
Connect the BRI facility to the "U" interface side of the customer provided NT-1 Unit.
Then connect the S/T side of the NT-1 unit to the BRI interface card in the iDCS 500
system as shown in
Figure
Figure 5–7.
OPTIONS IN iDCS 500
Super Frame (SF) or D4
Extended Super Frame (ESF)
AMI or B8ZS
5–8.
5.2
Home Page
Table of Contents
INSTALLATION
PART 5 MARCH 2004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Officeserv

Table of Contents