TECHNICAL MANUAL
enable a card the system will partially enable certain cards to maximize the capacity of
the power supply. The following table lists the cards that will be partially enabled.
Note: A single card can never be powered by both PSUs at the same time.
Card Type
16 DLI
8 DLI
16 SLI
16 MWSLI
8 SLI
8 MWSLI
SLI
SVMi-8/SVMi-16E
4 BRI
E&M
DID
GTRK
MGI 2
WLI
To determine which PSU is supplying each card, or to determine if a card is turned on
or off or how many ports are active on a card MMC 806 can be used to display the
status of each card.
• P:1
The card is running on PSU 1
• P:2
The card is running on PSU 2
• P:N
The card is turned off
• [
]
The number of ports available
4.2 CONNECT POWER TO THE SYSTEM
During the initial installation, it is best to verify proper system operation before plugging
in any amphenol-type cables to the MDF. If you have already plugged the cables in,
unplug them.
Partial Power
YES
YES (No KDb Support)
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
NO