iDCS 500 Release 2 / OfficeServ
TECHNICAL MANUAL
detection. To install the SCM board remove the two (2) screws holding the MCP2
protective casing together
case together
(see Figure 3–9)
board face down over the two connectors, taking care to properly line them up and
press gently on the back of the board to seat it. The MCP2/SCP2 case can now be
reassembled if all required daughter boards have been installed.
Note:
Only one SCM board can be installed per system.
An SCM and MFM cannot be installed on the same processor card

3.7 MFM BOARD ON PROCESSOR CARD

(see Figure 3-11)
This board has no selectable options and installs in any available position of the MCP2
card when the system has M version software
than one cabinet or is using L version Software the MFM board must be installed in any
available position of the SCP2 card
LCP2 cards. Up to 3 MFM board can be installed in a system (one on the MCP2 or
SCP2 and one on each LCP2). The MFM board is used to provide an additional 12 DSP
circuits for DTMF and tone detection. To install the MFM board remove the two (2)
screws holding the MCP2 or LCP2 protective casing together
remove the 4 screws holding the SCP2 case together
the two halves of the case. Place the MFM board face down over the two connectors,
taking care to properly line them up and press gently on the back of the board to seat
it. The MCP2/LCP2/SCP2 case can now be reassembled if all required daughter boards
have been installed.
Note:
Only one MFM board can be installed on each processor card. The MFM
board can only be installed on the MCP2 card in an M version system.
An SCM and MFM cannot be installed on the same processor card

3.8 RCM BOARD

This board has a slide switch to switch between MF R2 and CID. This switch should
always be in the CID position. The RCM board installs in any available position of the
MCP2 card when the system has M version software. If the system has more than one
cabinet or is using L version Software the RCM board must be installed in any available
position of the SCP2 card
Up to 3 RCM boards can be installed in a system (one on the MCP2 or SCP2 and one
on each LCP2). The RCM board is used to provide 14 Caller ID DSP circuits for Caller
ID detection on loop start trunks (TRK B1 and TRK C1). To install the RCM board
remove the two (2) screws holding the MCP2 or LCP2 protective casing together
Figure 3–7)
or remove the 4 screws holding the SCP2 case together
and separate the two halves of the case. Place the RCM board face down over the two
(see Figure 3–7)
or remove the 4 screws holding the SCP2
and separate the two halves of the case. Place the SCM
(see Figure
(see Figure 3–3)
(see Figure 3-13)
(see Figure 3–3)
or any available position of the LCP2 cards.
3.8
Home Page
INSTALLATION
PART 3 MARCH 2004
3–2). If the system has more
or any available position of the
(see Figure 3–7)
(see Figure 3–9)
and separate
(see Figure 3–9)