Table Of Contact Id Event Codes - ADEMCO N7227V5 Installation And Setup Manual

Vista security system installation and setup guide
Hide thumbs Also See for Ademco N7227V5:
Table of Contents

Advertisement

VISTA-10SE Installation and Setup Guide
The following describes each format in greater detail.
3+1 and 4+1 Standard Formats
3+1 and 4+1 Expanded Formats
4+2 Format
ADEMCO Contact ID
Reporting Format
ADEMCO Contact ID Reporting takes the following format:
where: CCCC = Customer (subscriber) ID
NOTE: For a complete list of event codes, refer to the central office receiver manual.
Code
Definition
110
Fire Alarm
121
Duress
122
Alarm, 24-hour Silent
123
Alarm, 24-hour Audible Panic
131
Alarm, Perimeter, Burg.
132
Alarm, Interior, Burg.
134
Alarm, Entry/Exit, Burg.
135
Alarm, Day/Night, Burg.
150
Alarm, 24-Hour Auxiliary
301
AC Power
302
Low System Battery/Battery Test Fail
321
Bell/Siren Trouble
333
Expansion Module Fail
344
Trouble, RF Jam Detect
353
Long-Range Radio Trouble
System Communication Programming
Programming information of those data fields that affect communications between the
control and the central station is included in the sections DATA FIELD DESCRIPTIONS and
ZONE PROGRAMMING ( 56 and 58 menu modes).
20-2
Comprise a 3- (or 4-) digit subscriber number and a single-digit
report code (e.g., Alarm, Trouble, Restore, Open, Close, etc.).
Comprise a 3- (or 4-) digit subscriber number, and a two-digit re-
port code. The first digit is displayed on the first line. On the
second line, the first digit is repeated 3 (or 4) times and is
followed by the second digit. This is the "expanded" digit.
Comprises a 4-digit subscriber number and 2-digit report code.
Comprises a 4-digit subscriber number, 1-digit event qualifier
("new" or "restore"), 3-digit event code, and 3-digit zone number,
user number, or system status number (see the following page).
CCCC Q EEE GG ZZZ
Q = Event qualifier, where:
E = new event , and R = restore
EEE = Event code (3 hexadecimal digits)
GG = Always 00.
ZZZ = Zone/contact ID number reporting the alarm, or user number for open/close reports.
System status messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location.

TABLE OF CONTACT ID EVENT CODES

Code
Definition
373
Fire Loop Trouble
374
Exit Error Alarm
380
Trouble (Global)
383
RF Sensor Tamper
384
RF Sensor Low Battery
401
O/C by User
406
Cancel by User
407
Remote Arm/Disarm (Download)
408
Quick Arm AWAY/MAX
441
Armed STAY/INSTANT, Quick Arm
STAY/INSTANT
570
Bypass
601
Test, Manually Triggered
602
Periodic Test
606
AAV to follow