In This Section
About Long-Range Radio
Wiring Connections
About Long-Range Radio
If output to Long-Range Radio (LRR) is selected, all messages that are programmed to go to
the primary telephone line receiver are also sent to any LRR that can operate in ECP mode.
These messages (by telephone or radio) are sent in Contact ID format (not affected by entry
in field 46).
U L
For UL installations, Long-Range Radio must be disabled ( 27 = 0).
The data line is supervised, as well as certain functions in the radio. If communication is lost
or a trouble develops, an attempt is made to send a message via both radio and telephone to
the Central Station.
For complete information, see the manual that accompanies the radio.
Wiring Connections
Connect the data in/data out terminals and voltage terminals of the LRR being used, to the
control's terminals as shown below.
AUX. POWER RTN
TO CONTROL (DATA IN)
DATA OUT FROM CONTROL
Programming for Long-Range Radio
Programming for the Long-Range Radio and/or Dynamic Signaling feature that follows is
explained in the DATA FIELD DESCRIPTIONS section (fields 27 and 93).
_
4
+
5
AUX. POWER
6
7
TERMINALS
ON CONTROL
PANEL
Figure 14. Long-Range Radio Connections
Long-Range Radio
Programming for Long-Range Radio
Dynamic Signaling Feature
BLACK
7720PLUS/7820/7835C
LONG RANGE RADIO
RED
GREEN
RADIO DATA OUT
YELLOW
RADIO DATA IN
S E C T I O N
9–1