Section 12. Mechanics Of Programming; About Programming; Entering The Program Mode - ADEMCO N7227V5 Installation And Setup Manual

Vista security system installation and setup guide
Hide thumbs Also See for Ademco N7227V5:
Table of Contents

Advertisement

In This Section

About Programming

Entering Program Mode
Programming a Data Field
Reviewing a Data Field/Erasing an Entry
About Programming
This section provides information on how programming is performed in this system. It will
enable you to understand how to enter and exit the Programming mode, and how to program
the data fields and the user-friendly Interactive Menu modes ( 56, 58, 80, 81, 82). We
therefore urge you to read and understand the following before proceeding with any
programming.
If RF zones or relays are used, the following applicable program fields must be enabled before
doing any zone programming:
22 RF SYSTEM
25 OUTPUT RELAY MODULE
It is possible to program the system at any time, even at the installer's premises prior to the
actual installation. Simply apply power temporarily to the control and then program the unit
as desired.
You cannot enter the Programming mode unless the security system is disarmed.
There are two programming modes: Data Field programming and Interactive (Menu) mode
programming. Data Field programming is used for setting various system options.
Interactive programming is used for programming zone information, programming relay
outputs, inserting alpha descriptors (or custom words), and enrolling transmitter serial
numbers.
To program the system, you must use a 6139 2-line alpha keypad connected to the keypad
terminals on the control (4, 5, 6, and 7). Remember, the security system must be disarmed.
The alpha keypad need not remain in the system after programming.
Programming can also be performed remotely from the installer's office/home, using an IBM
personal computer, a modem, and COMPASS downloading software. See the REMOTE
PROGRAMMING AND CONTROL (DOWNLOADING) section.

Entering the Program Mode

You may use one of the following methods:
a) Press the [ ] and [#] keys at the same time within 50 seconds after power is applied to the
control; or
b) After power-up, enter 4 1 1 1 (Installer code) + 8 0.
This method is disabled if you exit the Program mode using 98 instead of 99. See the
paragraph titled, "Exiting the Program Mode," later in this section.
Mechanics of Programming
Interactive Menu Mode Programming
Loading Factory Defaults
Programming System Setup Fields
Exiting the Programming Mode
S E C T I O N
1 2
12–1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-10seVista-10se

Table of Contents