VISTA-10SE Installation and Setup Guide
VIP Module Wiring
The VIP Module is wired between the control panel and the premises handset(s). It listens
for touch-tones on the phone line and reports them to the control panel. During on-premises
phone access, it powers the premises phones; during off-premises phone access, it seizes the
line from the premises phones and any answering machines.
NOTE: The phone lines must be in service for the VIP Module to function, even when
1. Make 12V (+) and (–) and data in and data out connections from the VIP Module to the
control, using the connector cable supplied with the VIP Module (see Figure 10).
Color Lead
GREEN
BLACK
RED
YELLOW
2. Insert the keyed connector at the other end of the connector cable into the mating header
on the VIP Module (see diagram on next page for location of the header).
3. Connect terminals 1 through 4 on the VIP Module as shown in the Wiring Table and in
the 4285/4286 wiring diagram that follows.
Use an RJ31X jack with a direct-connect cord and make all connections exactly as shown. If
the leads on the direct-connect cord are too short to reach their assigned terminals, splice
additional wires to them, as required.
4285/4286/4286
Terminal
1. Phone In (Tip)
2. Phone In (Ring)
3. Phone Out (Tip)
4. Phone Out (Ring)
5.
6. Output High
7. Output Rtn
If no touch-tones are produced following access to the security system from on-premises (this
problem may arise in rare cases), it may be necessary to reverse the wires connected to
terminals 3 and 4 on the VIP Module and the wires connected to terminals (17) and (18) on the
control. Figure 11 shows the wiring connections that will provide proper operation in most
cases.
Caller ID Units
If the telephone system on the premises includes a Caller ID unit, connect the ID unit
directly to the "Handset" terminals (17 and 18) on the control, as shown in Figure 11.
7-2
accessing the system from an on-premises phone.
Terminal On Control *
DATA IN (terminal 6)
AUX – (terminal 4)
AUX + (terminal 5)
DATA OUT (terminal 7)
4285/4286 WIRING TABLE
Connects to:
Terminal (17) on control.
Terminal (18) on control.
BROWN lead from direct-connect cord.
GRAY lead from direct-connect cord.
——
NOT USED
Not used (4285). Spkr High on 4286.
Not used (4285). Spkr Return on 4286.
*
These are the same connections
as
those
used
for
.
keypads
remote

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-10seVista-10se

Table of Contents