Lincoln Electric PIPEFAB Series Operator's Manual page 93

Table of Contents

Advertisement

PIPEFAB™ WELDING SYSTEM
MAINTENANCE
SAFETY PRECAUTIONS
READ AND UNDERSTAND ENTIRE SECTION BEFORE OPERATING MACHINE.
ELECTRIC SHOCK can kill.
• Do not operate with covers removed.
• Turn off power source before installing or servicing.
• Do not touch electrically hot parts.
• Turn the input power to the welding power source off at the fuse
box before working in the terminal strip.
• Only qualified personnel should install, use or service this
equipment.
ROUTINE MAINTENANCE
Rou�ne maintenance consists of periodically blowing out the machine, using a low-pressure air stream,
to remove accumulated dust and dirt from the intake and outlet louvers, and the cooling channels in the
machine.
Check weld cables, control cables and gas hoses for cuts.
Clean and �ghten all weld terminals.
PERIODIC MAINTENANCE
Calibra�on of the PipeFab™ is cri�cal to its opera�on. Generally speaking the calibra�on will not need
adjustment. However, neglected or improperly calibrated machines may not yield sa�sfactory weld
performance. To ensure op�mal performance, the calibra�on of output Voltage and Current should be
checked yearly.
Clean the drive rolls and inner wire guide and replace if worn.
Blow out or vacuum the inside of the feeder.
Inspect the motor brushes every 6 months. Replace if shorter than 0.5" (12.7mm).
-1
MAINTENANCE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents