Lincoln Electric PIPEFAB Series Operator's Manual page 76

Table of Contents

Advertisement

PIPEFAB™ WELDING SYSTEM
OPERATION
MEMORY OPERATION
FIGURE B.22
Memories can be saved for each welding process. These can be accessed by touching the applicable
memory bu�on labeled one through four.
To save a memory, hold the desired memory loca�on down un�l the screen indicates the memory is
saved.
When one memory is selected the LED will be lit, if any se�ngs are changed the LED will go out. If the
memory bu�on is pressed again, the se�ngs will revert to the se�ngs saved in the memory.
Four memories each can be saved in the S�ck process, TIG process, MIG Le� Feedhead, MIG Right
Feedhead, FCAW Le� Feedhead, and FCAW Right Feedhead.
Memory usage with remotes – If a TIG process is saved with a remote control connected, the remote
control must be connected for the memory to be func�onal. If Memory Only Mode is not enabled,
a warning will appear and can be bypassed.
B-25