PIPEFAB™ WELDING SYSTEM
FIGURE B.16
Operator Restric�ons
System Menu – OFF/ON, restricts changes to the System Menu.
Wave Controls – OFF/ON, restricts changes to Wave Controls (i.e. Pinch, Arc Force, Ul�marc).
Start/End Se�ngs – OFF/ON, restricts changes to Start/End Se�ngs.
Remote Range – OFF/ON, restricts changes to the Remote Range.
Trigger Interlock – OFF/ON, restricts changes to 2-step/4-step se�ngs.
Memory Only Mode – OFF/ON. Restricts the operator to only use processes and parameters stored in
Memories. In Memory Only Mode, if no memory exists for a given process, that process bu�on is
disabled when using the associated side of the feeder. For example, if Memory Only Mode is ON and
no memories are configured for a FCAW process on the le� feeder, the machine cannot be put in FCAW
mode when the le� feeder is ac�ve.
Memory Modifica�ons – Memory modifica�ons can be ENABLED, so parameters can be resaved within
the full range allowed by the machine. They can be DISABLED, so parameter cannot be resaved at all,
or they can be resaved WITHIN LIMITS, to allow fine tuning within preset limits.
B-19