Radiance Direct Vent Gas Heater
THIS APPLIANCE SHOULD BE CON-
NECTED TO THE GAS SUPPLY ONLY BY
A QUALIFIED GAS SERVICE TECHNICIAN.
FOLLOW ALL LOCAL CODES.
THERE MUST BE A GAS SHUT-OFF BE-
TWEEN THE STOVE AND THE SUPPLY.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove
shroud (when facing shroud) using two screws and
existing holes in shroud. (Fig. 52)
2. Run wires down back of stove, under bottom of rear
shroud to valve.
3. Attach wires to valve terminals. (Fig. 53)
Switch As-
sembly
Screws
Fig. 52 Attach switch assembly to rear shroud.
�������
The Radiance is operated with the front plate in place
with the doors open or closed. To open the front doors,
pull forward to separate the magnetic catch.
CAUTION: DO NOT TOUCH DOORS WHEN
HOT!
2828
Existing
Holes
ST315

Operation

��� ����� ����
����� ������
ST315
�� ��� ����� �����
attach switch assy
����� �������
����� ����� ��������
1/31/00 djt
�� ����� ������
Fig. 53 Attach switch wires to valve.

Thermostat Connection (optional)

Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.
Thermostat
Wire / Gauge
18
16
14
1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Fig. 53)

Install the Mesh and Grille

Place the mesh and grille on the top of the Radiance
stove to complete assembly.

Your First Fire

Read these instructions carefully and familiarize
yourself with the burner controls shown on Page 29.
Locate the pilot assembly, Figure 54. Follow the lighting
instructions on Page 30 exactly.
During the first fire, it is not unusual to smell some
odor associated with new logs, paint and metal being
heated. Odors should dissipate within the first eight to
ten hours, however, you can open a window to provide
fresh air to alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
56. If flame patterns are incorrect, turn the heater off.
Contact your dealer or a qualified gas technician for as-
sistance. Do not operate the heater until the pilot flame
is correct.
ST228
ST228
attach switch
wires to valve
12/99
Maximum Run
20 feet
20 - 40 feet
up to 60 feet
20012697