Vermont Castings RFS22 Installation Instructions & Homeowner's Manual
Vermont Castings RFS22 Installation Instructions & Homeowner's Manual

Vermont Castings RFS22 Installation Instructions & Homeowner's Manual

Free-standing fireplaces

Advertisement

Installation Instructions & Homeowner's Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch
Do not use any phone in your building.
Immediately call your gas supplier from
your neighbours phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier call
the fire department.
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
The Vermont Castings
Majestic Products Company
410 Admiral Blvd., Mississauga
Ontario, Canada L5T 2N1
www.majesticproducts.com / www.vermontcastings.com
Free-Standing
Fireplaces
RFS22
RFS32
RFS42
FOR YOUR SAFETY
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
Installation and service must be performed by a
qualified installer, Service agency or your gas
supplier.
10000834
11/01 Rev. 2

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings RFS22

  • Page 1: For Your Safety

    Installation and service must be performed by a qualified installer, Service agency or your gas supplier. The Vermont Castings Majestic Products Company 410 Admiral Blvd., Mississauga Ontario, Canada L5T 2N1 Fireplaces RFS22 RFS32 RFS42 DO NOT STORE 10000834 11/01 Rev. 2...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Majestic fireplace IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions ...
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CAN / CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code.
  • Page 4: Fireplace Dimensions

    FIREPLACE DIMENSIONS MODEL RFS22 26" 660mm 26" 660mm 1/4" 387mm 1/4" 488mm 5/8" 473mm 21" 533mm 1/2" 800mm 3/4" 451mm 5/8" 752mm 5/8" 244mm 1/4" 133mm – – – – – – MODEL RFS22 MODEL RFS32 MODEL RFS42 MODEL RFS32 25"...
  • Page 5: Gas Specifications

    4,500 ft. (1,370mm). Maintain the manifold pressure at 3.5 inches W.C. for Natural Gas and 10 inches W.C. for LP gas.) RFS22 / RFS32 / RFS42 CERTIFIED TO ANSI.Z21.88a-1998 / CSA 2.33a - M98 Vented Gas Fireplace Heaters GAS INLET &...
  • Page 6: Installation Of Remote Switch For Rn/Rp Gas Valve

    SWITCH FOR RN/RP GAS VALVE Install on/off switch assembly on either the rear right or left side of the RFS22/RFS32/RFS42 Gas Fireplace. 1. Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace.
  • Page 7: General Venting Information

    Note: Please refer to installation instructions supplied by chimney manufacturer prior to commencing installation. The RFS22/RFS32/RFS42 may be installed using 4" diameter single wall vent up to an existing masonry chimney.(Fig. 10) This vent should then be connected to a 4"...
  • Page 8: Retrofitting To An Existing Brick Chimney

    Retrofitting To An Existing Brick Chimney The CFM Majestic Products Company strongly recommends installing an approved chimney liner in an existing brick chimney. This will maximize the potential draft of the chimney and lessen the effects of slow chimney start up. This is important because many homes (including older renovated ones) have become much tighter with respect to air exchange (a home breathing).
  • Page 9: Operating Instructions

    Replacement of the rear glass (with gasket) as supplied by the manufacturer should be done by a licensed qualified person. LOUVRE REMOVAL RFS22 Remove the front louvre assembly by lifting up and outward on the assembly. RFS32 To remove louvres first remove the two (2) screws (Fig. 13) fastening the louvre assembly to the fireplace.
  • Page 10: Glass Cleaning

    Clean glass after first two weeks of operation. INSTALLATION OF LOGS & BURNER LAVA ROCK RFS22 & RFS32 1 . Remove front glass. (See "Glass Removal" section) 2. Remove logs from packaging. 3. Place rear log (KR4) on rear bracket (ensure log is...
  • Page 11: Cleaning Procedure

    Compare them to the pictorials illustrated below (Fig. 20, 21) . If any of the flames appear abnormal call a service person. 3/8" - 1/2" SIT VALVE RFS22 RFS32 RFS42 Turn clockwise to lower flame height.
  • Page 12: Lighting Instructions

    LIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNI N G: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.
  • Page 13: Troubleshooting Gas Control (Sit 630)

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES 1. Spark ignitor will not light A.
  • Page 14: Troubleshooting Gas Control (Sit 820)

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES 1. Spark ignitor will not light A.
  • Page 15: Troubleshooting Gas Control (Honeywell)

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE START • GAS SUPPLY ON PILOT LIGHTS WITH PIEZO IGNITOR PILOT STAYS LIT PILOT LIGHTS MAIN BURNER SYSTEM OK. CHECK • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.
  • Page 16: Replacement Parts List

    Remote Wire Harness with Terminals Vent Safety Switch Vent Safety Switch Wiring Harness Clamp Frame Window Ceramic Refractory Lining Kit (Not Shown) Ceramic Refractory Bay (ONLY Bay Set) (Not Shown) Top or Bottom With Magnets RFS22 RFS32 10000160 10000160 57897 57897 10000198...
  • Page 17: Replacement Parts Pictorial

    REPLACEMENT PARTS 3a/b 5/6a/b 9 a/b 7a/b 10 a/b 36 a/b 25a/b 12 17 8 a/b 21a,b 24 a/b #1 COMPLETE LOG SET RFS42 #1 - COMPLETE LOG SET -- RFS22/RFS32 - 17 -...
  • Page 18: Options

    OPTION S REMOTE CONTROL For units with RN/RP valves MRC1 - On/Off Button Remote Control MRC2 - Temperature Control Remote MRC3 - Temperature Control w/digital display & 24 hour programmable clock - Wall Mounted Thermostat - 18 -...

This manual is also suitable for:

Rfs32Rfs42