Installation and service must be performed by a qualified installer, Service agency or your gas supplier. The Vermont Castings Majestic Products Company 410 Admiral Blvd., Mississauga Ontario, Canada L5T 2N1 Fireplaces RFS22 RFS32 RFS42 DO NOT STORE 10000834 11/01 Rev. 2...
TABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Majestic fireplace IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions ...
INSTALLATION INSTRUCTIONS This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CAN / CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code.
4,500 ft. (1,370mm). Maintain the manifold pressure at 3.5 inches W.C. for Natural Gas and 10 inches W.C. for LP gas.) RFS22 / RFS32 / RFS42 CERTIFIED TO ANSI.Z21.88a-1998 / CSA 2.33a - M98 Vented Gas Fireplace Heaters GAS INLET &...
SWITCH FOR RN/RP GAS VALVE Install on/off switch assembly on either the rear right or left side of the RFS22/RFS32/RFS42 Gas Fireplace. 1. Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace.
Note: Please refer to installation instructions supplied by chimney manufacturer prior to commencing installation. The RFS22/RFS32/RFS42 may be installed using 4" diameter single wall vent up to an existing masonry chimney.(Fig. 10) This vent should then be connected to a 4"...
Retrofitting To An Existing Brick Chimney The CFM Majestic Products Company strongly recommends installing an approved chimney liner in an existing brick chimney. This will maximize the potential draft of the chimney and lessen the effects of slow chimney start up. This is important because many homes (including older renovated ones) have become much tighter with respect to air exchange (a home breathing).
Replacement of the rear glass (with gasket) as supplied by the manufacturer should be done by a licensed qualified person. LOUVRE REMOVAL RFS22 Remove the front louvre assembly by lifting up and outward on the assembly. RFS32 To remove louvres first remove the two (2) screws (Fig. 13) fastening the louvre assembly to the fireplace.
Clean glass after first two weeks of operation. INSTALLATION OF LOGS & BURNER LAVA ROCK RFS22 & RFS32 1 . Remove front glass. (See "Glass Removal" section) 2. Remove logs from packaging. 3. Place rear log (KR4) on rear bracket (ensure log is...
Compare them to the pictorials illustrated below (Fig. 20, 21) . If any of the flames appear abnormal call a service person. 3/8" - 1/2" SIT VALVE RFS22 RFS32 RFS42 Turn clockwise to lower flame height.
LIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNI N G: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.
TROUBLE SHOOTING THE GAS CONTROL SYSTEM Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES 1. Spark ignitor will not light A.
TROUBLE SHOOTING THE GAS CONTROL SYSTEM Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES 1. Spark ignitor will not light A.
TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE START • GAS SUPPLY ON PILOT LIGHTS WITH PIEZO IGNITOR PILOT STAYS LIT PILOT LIGHTS MAIN BURNER SYSTEM OK. CHECK • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.
OPTION S REMOTE CONTROL For units with RN/RP valves MRC1 - On/Off Button Remote Control MRC2 - Temperature Control Remote MRC3 - Temperature Control w/digital display & 24 hour programmable clock - Wall Mounted Thermostat - 18 -...