Flame Characteristics; Inspecting The Venting System - Vermont Castings DVRT41 Homeowner's Installation And Operating Manual

Direct vent gas fireplace
Table of Contents

Advertisement

SIT 820 Valve
Turn
counterclockwise
to increase
flame height
Fig. 50 Flame adjustment knob for SIT valve.

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to the
pictorials illustrated below. (Figs. 51, 52) If any of the
flames appear abnormal call a service person.
3/8" - 1/2"
(10 - 13 mm)
SIT Pilot
Fig. 51 Correct pilot flame appearance.
10006740
Turn clockwise
to decrease
flame height
Fig. 52 Correct burner flame appearance for DVRT41.
PSE Pilot
This appliance venting system is designed and con-
structed to develop a positive flow adequate to remove
flue gases to the outside atmosphere.
Any foreign objects in the venting system, except those
designed specifically for the venting system, may cause
F584-703
spillage of flue gases.
To inspect the venting system, make sure the main gas
valve is off. Remove window frame assembly (Refer to
Window Frame Assembly Removal Section). Using a
flashlight, check the area above the baffle in the com-
bustion dome. Clean if necessary.