Initial Lighting Of The Fireplace; Flame & Temperature Adjustment; Flame Characteristics; Inspecting The Venting System - Vermont Castings DVR28IN Homeowner's Installation And Operating Instructions Manual

Intercontinental collection direct vent gas fireplace
Table of Contents

Advertisement

Vermont Castings DVR28 Direct Vent Gas Fireplace
Initial Lighting of Fireplace
1. Install batteries supplied with remote control accord-
ing to instructions on Page 22.
2. Install AA batteries supplied in bolt bag into "Bat-
tery Pack" on bottom side of fireplace according to
instructions on Page 23. NOTE: Sheet metal holding
box may need loosened to slide battery pack out.
3. Press and hold learn button on back side of module
for 10 seconds. You should hear a series of beeps.
Press and release learn button. You should hear a
single beep immediately. Press either the "ON" or
"OFF" button on the remote control transmitter. You
should hear a series of beeps indicating the trans-
mitter code has been learned.
Front of Fireplace
Electronic
Module
Back of Fireplace
Bottom View
Fig. 33 Battery pack location on bottom of fireplace.
Flame & Temperature Adjustment
To adjust Hi/Lo setting, push either the high or low con-
trol button on remote control transmitter.
Fig. 34 Flame adjustment for American Flame valve.
FP1796
Wireless remote
3/07
20
Battery Pack
Learn Button
(Back of electronic
control module)
FP1815
������
������� ����
����
ON
OFF
HI
LO
FP1759

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to Fig-
ures 35-36. If any of the flames appear abnormal call a
service person.
Fig. 35 Correct pilot flame appearance.
Fig. 36 Correct DVR28 flame. Center flame should be ap-
proximately 5¹⁄₂" (140 mm) above bottom window frame.

Inspecting the Venting System

This appliance venting system is designed and con-
structed to develop a positive flow adequate to remove
����� ����� �����
flue gases to the outside atmosphere.
����
Any foreign objects in the venting system, except those
designed specifically for the venting system, may cause
spillage of flue gases.
To inspect the venting system, make sure the main gas
valve is off. Remove window frame assembly (Refer to
Window Frame Assembly Removal Section). Using a
flashlight, check the area above the baffle in the com-
bustion dome. Clean if necessary.
FP1778
������
��� �����
����
20012301
LG480

Advertisement

Table of Contents
loading