Vermont Castings DVRT41 Homeowner's Installation And Operating Manual page 37

Direct vent gas fireplace
Table of Contents

Advertisement

Center
Plunger
Blue -
NG
Red - LP
Fig. 65 Depressd and turn center plunger.
Manifold
Assembly
Manifold Mounting
Screw
Orifice
Fig. 66 Remove manifold assembly.
Rear Burner Orifice:
Refer to Conversion Kit
Orifice Chart
CO124
Fig. 67 Burner orifice replacement.
Shutter
Burner Pan
Retaining
Screw
Air Shutter
Front View
Fig. 68 Remove air shutter from burner pan.
10.Reinstall manifold mounting screw.
NOTE: It is not necessary to remove the pilot tube for
conversion.
11. Loosen pilot hood turning counterclockwise using a
7/16" wrench. (Fig. 69)
12. Remove pilot orifice with needlenose pliers. (Fig.
70)
13. Install conversion pilot orifice.
14. Reinstall pilot hood. Be sure to align pilot hood with
index marks.
10006740
Motor Top Cap
FP1037b
Pilot Location
Burner Pan
CO101a
Front Burner Orifice:
Refer to Conversion Kit
Orifice Chart
CO103
DVRT41Direct Vent Gas Fireplace
Index
Marks
Pilot
Bracket
Fig. 69 Remove pilot hood.
Fig. 70 Remove pilot orifice.
15.Turn the gas supply valve and gas valve on and test
for leaks. Use a 50/50 solution of liquid soap and
water to test for leaks at gas fittings and joints. Apply
water/soap solution with brush only - do not over
apply. NEVER test with an open flame.
16.Follow procedure on rating plate to light the pilot.
Check for leaks.
17.Turn main burner on and check for leaks.
18.Install logs. Refer to Page 24 for proper log place-
ment.
Installation complete.