CONSTANT SPIN
POSSIBLE CAUSE
TO CORRECT
Inoperative timer.
Test timer and replace if inoperative.
Washtub does not stop spinning within seven
Replace brake pads.
seconds alter loading door is opened.
Excessive wear on brake pads, or missing
Replace brake pads.
brake pads.
Shorted or incorrect wiring.
Refer to appropriate wiring diagram.
46.
UNIT STOPS IN CYCLE; QUITS AFTER A COUPLE LOADS; IS INTERMITTENT
.
.
:
Belt is tacky and does not allow proper slip.
Belt tension is too grea: and does not allow
proper slip.
Inoperative timer.
Broken, loose, or incorrect wiring.
Motor overload protector has cycled.
Motor switch functions inoperative.
Brake, transmission, or motor have locked
up and will not turn.
47.
WASHER IS LOCKED UP OR BINDING
POSSIBLE CAUSE
Excessive belt tension.
Bind in upper or lower bearing.
Bind in water pump.
Bind in transmission.
Brake pads binding.
Incorrect voltage.
RS3100002
(37 400R3)
Aev.3
TO CORRECT
Check belt and replace if defective.
Make sure helper spring (if present) and idler spring
are properly connected.
Test timer and replace if inoperative.
Refer to appropriate wiring diagram.
Wait two or three minutes for overload protector to
reset. If protector cycles repeatedly, refer to
paragraph 43.
Refer to SECTION V to check switch functions.
Check that all these components are able to move
freely.
TO CORRECT
Replace belt and/or idler spring.
Replace bearing.
Replace pump.
Repair or replace transmission.
Free binding pads, or replace pads.
Contact local utility company, or have a qualified
electrician check power supply.