ERA & EBD SERIES ELECTRIC FRYERS - TROUBLESHOOTING
KLEENSCREEN FILTERING
SYSTEM
SYMPTOM
Shortening not filtering, pump motor is
energized.
Shortening not discarding, pump motor
energized.
Pump motor is not energized to circulate
shortening thru filtering system.
Pump motor is not energized to discard
shortening.
F25385 (May 2010)
POSSIBLE CAUSES
1.
Filter screen plugged.
2.
Clog in filter system lines.
NOTE: If using solid shortening, when all filtered shortening
is returned to the fry tank and filter power switch is off, open
the filter drawer approximately one inch. Allow the remaining
shortening in the line to drain into the filter tank to prevent
possible clogging after the shortening cools and solidifies.
Close the filter drawer when complete.
3.
Shortening below 300°F to thick.
4.
Fill solenoid valve malfunction.
5.
Interconnecting wiring malfunction.
6.
Pump is inoperative.
1.
Filter screen plugged.
2.
Clog in filter system lines.
NOTE: If using solid shortening, when all filtered shortening
is returned to the fry tank and filter power switch is off, open
the filter drawer approximately one inch. Allow the remaining
shortening in the line to drain into the filter tank to prevent
possible clogging after the shortening cools and solidifies.
Close the filter drawer when complete.
3.
Shortening below 300°F to thick.
4.
Discard valve switch malfunction (N.O. contacts not
closing to energize R3 filter relay coil).
5.
R3 fill relay malfunction (contacts remain closed).
NOTE: The fill solenoid valve should not be energized
during discard operation so that shortening will flow thru
manual discard valve only.
6.
Discard valve mechanical malfunction.
7.
Discard hose connection not fully engaged.
8.
Pump is inoperative.
1.
Filter switch on cooking controls not turned on.
2.
Pump needs reset. (Reset button located on pump)
3.
R3 filter relay malfunction.
4.
Interconnecting wiring malfunction.
5.
Pump motor inoperative.
1.
Filter switch on cooking controls not turned on.
2.
Pump needs reset. (Reset button located on pump)
3.
Discard handle (yellow) not extended.
4.
R3 filter relay malfunction.
5.
Interconnecting wiring malfunction.
6.
Pump motor inoperative.