Fault Code Troubleshooting; F1: Blower Fault - TurboChef 3240 Service Manual

High h conveyor oven
Table of Contents

Advertisement

Fault Code Troubleshooting

From
, you can test separate oven components to help diagnose an issue. To access
TEST MODE
, see page 16.
MODE
6
Open Left End
Bell.
Is a fault code
present on the
BMSC?
NO
YES
CF, cF, F1, or GF fault: EPM module
is faulty. Replace BMSC (page A-8 =
lower, page A-12 = upper).
AF fault: Temperature is too high in
housing. Check cooling system (page
41).
Any other fault:
Call technical support.
To
From
Blue
Brown
Blue
White
Brown
White
Blue, Brown, or White
Green
Figure 37: Motor Windings Resistance Table
Troubleshooting:
F1:BLOWER FAULT (Blower Failure)
Access the
TEST MODE
(page 16)
Are the status indicators at
NO
location 6 and 7 present
(pages 18-19)?
7
Is the blower motor
spinning freely?
Open the Right
End Bell.
Is a fault code
present on the
BMSC?
YES
YES
NO
Is the wiring connected properly?
Check the BMSC, blower motor, and
I/O control board.
Description
Winding (A-B)
Winding (A-C)
Winding (B-C)
Windings to chassis
.
YES
NO
YES
Do resistance measurements
between windings and
chassis agree with values on
motor windings resistance
table (Figure 37)?
YES
Replace BMSC (page A-8 =
lower, A-12 = upper).
Expected Resistance
5.1-5.5 W
5.1-5.5 W
5.1-5.5 W
Open
TEST
Check the I/O control
board, BMSC, and blower
motor wiring (page 45).
Remove obstruction or, if
necessary, replace blower
motor (page A-8 = lower,
A-12 = upper).
Replace the
NO
blower motor
(page A-8 =
lower, A-12 =
upper).
Correct wiring
or replace I/O
control board,
BMSC, or
blower motor
if damaged
NO
(page A-8 =
lower, A-12 =
upper).
3 1