Thermostatic Switch - KYMCO MXU 450i Service Manual

Hide thumbs Also See for MXU 450i:
Table of Contents

Advertisement

Brakelight S\Nitch
(Pressure)
The
brakelight
switch
is
located
on t he
top
Clfthe
am>-
iliary brake master cylinder
and
is
pressure
activated
by U1e
hand
brake
or
the
auxiliary
brake ptedal.
Titis
switch
also activates tl1c
start-in-gear
(SIG
)
relay
in
the
power
distribution
module (PDM).
•NOTE:
The
ignition
switch
must be in the ON
position.
VOLTAGE
(Wiring
Harness Side)
I.
Set
the
mete
r selector
to
the DC
Vol
tage position.
2.
Connect
the
red
teste
r
to
the
brown/black
wire;
then
co1mcct
the
black
tester
lead
to
grou111d
.
3. The
meter must
sho'rv
battery
voltage.
•NOTE:
If
the
meter
shows
no battery voltage,
troubleshoot
the
battery, fuse,
switch
,
or
the
main
wiring
harness.
•NOTE:
If
the meter
shows
battery
voltage,
the
main
wiring
harness is
good;
proceed to test
the
switch/component
or
connector.
RESISTANCE (Switch)
&
CAUTION
11
Always disconnect the battery
when
porformlng
resistance tests
to
avoid
damaging
t
he
mul·timeter.
l.
Remove the
spade
connectors from
U1e brake
switch.
2.
Set
the
meter
selector
to
the
OHMS
position.
3.
Com1ect
the red tester lead
to
one
switch
tc
nninal:
tbeu
connect
U1e black
tester
lead
to
U1e
other
switch tenn
inal.
4.
When
the brake
pedal
is
depressed.
the
meter
must
sho"
less
than
I
ohm.
•NOTE
:
If the
meter
shows
more
than
1 ohm of
resistance,
replace
the
switch.
THERMOSTATIC SWITCH
I.
Connect
the
rueter
]cads
(selector
i11
the
OHMS
position)
to
the
switcb
contacts.
2.
Suspend
the switch
and
a
thcmwmeter in a
con-
tainer
of cooking
oil:
then
heat
the
oil.
•NOTE:
Neither the switch nor the thermometer
should be allowed to touch the bottom of the
con-
tainer or
inaccurate
readings
will
occur.
Use wire
holders
to
suspend switch
and thermometer.
Wear insulated gloves and
safety
glasses.
Heated oil
can
cause severe
burns.
Thermost~tic
Switch
HotPlate
733·554C
3.
When the coolant
temperature
is
lower than 85
"C,
the thermostatic switch OFF.
When coolant
temperature
is over 90
·c ,
the
thermostatic switch ON.
5-3