Ê Secure each hard disk drive in the HDD cage with four screws (C26192-Y10-
C56). Screw torque: 0.4 Nm
Ê Reconnect the SATA and power cables to the hard disk drive(s).
Figure 27: Inserting the hard disk drive cage into the chassis
Ê Insert and slide the hard disk drive cage into the chassis as shown until the
two hooks on the HDD cage engage with the retaining screws (1).
Ê Fasten the two screws to secure the hard disk drive cage (C26192-Y10-
C67). Screw torque: 0.6 Nm
Ê Reinstall the front panel module as described in
panel module" on page
Ê Close the server as described in
PRIMERGY CX120 S1
32.
section "Closing the server" on page
Service Supplement
Replacing the hard disk drives
section "Replacing the front
31.