Specification for brine/water heat pumps
Type BWC-M
Heating performance data to Commission Regu-
lation (EU) No 813/2013 (average climatic condi-
tions)
Low temperature applications (W35)
Energy efficiency
η
S
Rated heating output P
rated
Seasonal coefficient of performance (SCOP)
Medium temperature applications (W55)
Energy efficiency
η
S
Rated heating output P
rated
Seasonal coefficient of performance (SCOP)
Sound power level to ErP(B0/W55)
Specification for water/water heat pumps
400 V appliances
Type BWC in conjunction with "conver-
sion kit for water/water heat pump"
Heating performance data to
EN 14511 (W10/W35, 5 K
spread)
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance
(COP)
Brine (primary intermediate cir-
cuit)
Capacity
Minimum flow rate
Residual head at minimum flow
rate
Max. flow temperature (brine in-
let)
Min. flow temperature (brine in-
let)
Heating water (secondary cir-
cuit)
Capacity
Minimum flow rate
Residual head at minimum flow
rate
Max. flow temperature
%
kW
%
kW
dB(A)
201.B06
kW
kW
kW
ε
l
l/h
mbar
kPa
°C
°C
l
l/h
mbar
kPa
°C
(cont.)
201.B06
180
6
4.7
118
6.0
3.14
40
201.B08
201.B10
7.53
9.80
5.80
8.52
1.23
1.57
6.11
6.24
3.3
3.3
1440
2120
570
300
57.0
30.0
25
25
7.5
7.5
3.3
3.5
650
850
610
680
61.0
68.0
65
65
Specification
201.B08
201.B10
194
9
5.04
122
8
3.24
44
201.B13
201.B17
13.41
16.89
11.61
14.46
2.11
2.61
6.37
6.46
3.9
4.5
2880
3300
770
624
77.0
62.4
25
25
7.5
7.5
3.8
4.6
1160
1450
625
660
62.5
66.0
65
65
188
11
4.91
123
10.0
3.27
46
22.59
19.17
3.68
6.15
5.9
4450
290
29.0
25
7.5
5.7
1990
540
54.0
65
93