Electrical connection
Main PCB (230 V~ function components)
Information regarding the connection values
The specified output is the recommended connected
load.
Total output of all components connected directly to
the heat pump control unit (e.g. pumps, valves, mes-
sage facilities, contactors): Max. 1000 W
If the total output is < 1000 W, the individual rating of
a component (e.g. pump, valve, message facility,
contactor) can be greater than specified. However,
the breaking capacity of the relevant relay must not
be exceeded.
The specified current indicates the max. switching
current of the switching contact. Observe total cur-
rent of 5 A.
Plug
sYA
Terminals
Function
211.5
Cooling control via NC-Box
NC
NC function (natural cooling)
Plug
sYS
Terminals
Function
212.1
Control of active cooling function
AC
212.2
Heating circuit pump for heating cir-
cuit without mixer A1/HC1
A1
212.3
DHW circulation pump
212.4
3-way diverter valve for heating water
buffer cylinder bypass or heat pump
in the case of dual alternative mode
(cont.)
Set the required parameters during commissioning:
See page 55 onwards.
Explanation
Connection values
Output: 10 W
Voltage: 230 V~
Max. switching current: 4(2) A
Explanation
Components for AC cooling
Supply values
Output: 10 W
Voltage: 230 V~
Max. switching current: 4(2) A
This pump is connected in addition to the secondary
pump if a heating water buffer cylinder is installed.
Connect a temperature limiter in series to restrict the
maximum temperature of underfloor heating circuit (if
installed).
Note
In systems without heating water buffer cylinder the
temperature limiter is connected to X3.2/X3.14 at the
luster terminals: See chapter "Temperature limiter to re-
strict the maximum temperature of underfloor heating".
Supply values
Output: 100 W
Voltage: 230 V~
Max. switching current: 4(2) A
Supply values
Output: 50 W
Voltage: 230 V~
Max. switching current: 4(2) A
Supply values
Output: 130 W
Voltage: 230 V~
Max. switching current: 4(2) A
Installation sequence
29

Hide quick links:

Advertisement

Table of Contents
loading