Image 12-28
6. Slide the anode connector into position on the Lamp House as illustrated.
Caution:
Avoid any tension on the anode wire, ensuring there is no mechanical stress on the lamp.
Image 12-29
7. Install the UV blocker assembly as illustrated. While supporting the lamp, via the Lamp House side opening, guide the UV blocker
(with supporting mechanism) into position and engage it with the lamp.
Install the UV blocker assembly as illustrated. Use the opening at the side of the Lamp House to guide the anode pin of the
xenon lamp into the anode supporting mechanism of the UV blocker.
Note: Make sure that the notch (reference 12 of image 12-30) of the UV blocker assembly matches with the gap (reference 12
of image 12-30) of the anode connector.
12
Image 12-30
8. Secure the UV blocker by fastening the three quarter turn screws (reference 5 image 12-31) as illustrated.
R5977692 DP2K-S SERIES 10/12/2012