Scheimpflug Adjustment - Barco DP2K-S Series User And Installation Manual

Table of Contents

Advertisement

10. Scheimpflug
10.2 Scheimpflug adjustment
Necessary tools
3mm Allen wrench.
13mm nut driver.
10mm nut driver.
Preparation steps:
1. Ensure that the throw ratio of the installed lens matches the requirements of the application (projection distance and screen size).
2. Ensure that the correct lens parameters are activated. (See user guide of the Communicator chapter Installation > Advanced >
Lens parameters)
Note: Selecting the wrong lens parameters will result in an unexpected behavior of the lens when using macros for switching
between FLAT and SCOPE (change in picture size and focus).
3. Perform a lens HOME & RETURN operation. (See user guide of the Communicator chapter Installation > Advanced > Lens
parameters)
4. Project the green focus test pattern.
Image 10-3
5. Zoom the lens for maximum image on the screen (WIDE).
6. Is it possible to focus the center of the projected image?
If yes, the Back Focal Length is OK. Proceed with the next step.
If no, the Back Focal Length needs realignment. Proceed with the procedure "Back Focal Length adjustment", page 64.
7. Unlock and turn out the 4 set screws (reference 11 image 10-4) of the Lens Holder by 1 centimeter. Use a 10mm nut driver for
the lock nuts (reference 21 image 10-4) and use a 3mm Allen wrench for the set screws.
Image 10-4
8. Fully loosen the Scheimpflug nut at the lower left of the Lens Holder (reference 4 image 10-5). Use a 13mm nut driver.
9. Optimize the focus of the projected image in the center of the screen (F) using the motorized focus control (Local Keypad).
4
Image 10-5
60
4
11
21
11
FOCUS
R5977692 DP2K-S SERIES 10/12/2012
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp2k-10s series

Table of Contents