Signal Connection - Siemens SINAMICS S120 1PM6 Configuration Manual

Hollow-shaft motors for main spindle drives
Table of Contents

Advertisement

6.2

Signal connection

DRIVE-CLiQ is the preferred method for connecting the encoder systems to SINAMICS.
Motors with a DRIVE-CLiQ interface can be ordered for this purpose. Motors with a DRIVE-
CLiQ interface can be directly connected to the associated motor module via the available
MOTION-CONNECT DRIVE-CLiQ cables. The MOTION-CONNECT DRIVE-CLiQ cable is
connected to the motor in degree of protection IP67. The DRIVE-CLiQ interface supplies
power to the motor encoder via the integrated 24 VDC supply and transfers the motor
encoder and temperature signals and the electronic type plate data, e.g. a unique
identification number, rating data (voltage, current, torque) to the control unit. The MOTION-
CONNECT DRIVE-CLiQ cable is used universally for connecting the various encoder types.
These motors simplify commissioning and diagnostics, as the motor and encoder type are
identified automatically.
Encoder connection on motors with DRIVE-CLiQ
Motors with DRIVE-CLiQ interfaces can be directly connected to the corresponding Motor
Module via the available MOTION-CONNECT DRIVE-CLiQ cables. This data is transferred
directly to the Control Unit.
Figure 6-3
1PM6/1PM4 Hollow-Shaft Motors for Main Spindle Drives
Configuration Manual, PPMS, 04/2008, 6SN1197-0AD23-0BP0
Encoder connection on motors with DRIVE-CLiQ
Connection methods
6.2 Signal connection