Information On The Application Of Motors; Transportation / Storage Before Use; Ambient Conditions - Siemens SINAMICS S120 1PM6 Configuration Manual

Hollow-shaft motors for main spindle drives
Table of Contents

Advertisement

Information on the application of motors

7.1

Transportation / storage before use

During transportation and if the motors are out of operation for a long period of time, the
cooling circuit must be completely emptied to protect against frost damage and corrosion.
The motors should be stored indoors in dry, low-dust and low-vibration (v
rooms. The motors should not be stored longer than two years at room temperature (+5 °C
to +40 °C) to retain the service life of the grease.
Read the additional notes regarding transportation and storage in the operating instructions.
7.2

Ambient conditions

Table 7-1
Operation
Storage/transport
Derating
If other conditions prevail (ambient temperature > 40° C or installation altitude > 1000 m
above sea level), the permissible torque/power must be defined using the factors from the
table (torque/power reduction according to EN 60034-6).
For ambient temperatures > 50°C, please contact your local Siemens office.
Ambient temperatures and installation altitudes are rounded off to 5° C or 500 m
respectively.
Table 7-2
altitude above sea level
1PM6/1PM4 Hollow-Shaft Motors for Main Spindle Drives
Configuration Manual, PPMS, 04/2008, 6SN1197-0AD23-0BP0
Ambient temperature for operation and storage/transport
Factors to reduce the torque/power (de-rating)
Installation
1000
1500
2000
2500
3000
3500
4000
T = –15 °C to +40 °C (without any restrictions)
T = -20 °C to +70 °C
Ambient temperature in °C
40
1.00
0.97
0.94
0.90
0.86
0.82
0.77
< 0.2 mm/s)
rms
45
0.96
0.93
0.90
0.86
0.82
0.79
0.74
7
50
0.92
0.89
0.86
0.83
0.79
0.75
0.71
87