Siemens SINAMICS S120 1PM6 Configuration Manual page 41

Hollow-shaft motors for main spindle drives
Table of Contents

Advertisement

Connection values of separately driven fans
Table 3-7
400 V 3 AC, 50 Hz (voltage tolerance ± 10 %)
400 V 3 AC, 60 Hz (voltage tolerance ± 10 %)
480 V 3 AC, 60 Hz (voltage tolerance +6% / –10%)
Recommended connection
The fan is connected via a terminal box. The fan must be operated through motor circuit
breakers. The direction of rotation of the fans must be checked.
Figure 3-2
Note
The motor circuit breaker must be set to value I
1PM6/1PM4 Hollow-Shaft Motors for Main Spindle Drives
Configuration Manual, PPMS, 04/2008, 6SN1197-0AD23-0BP0
Supply voltage, rated current and power draw of separately driven fans
Voltage
Recommended connection
Mechanical properties of the motors
SH 100
I
[A]
I
[A]
N
max
0,15
0,3
0,15
0,3
0,15
0,3
of the fan.
max
3.1 Cooling
SH 132
I
[A]
I
[A]
N
max
0,25
0,36
0,25
0,36
0,30
0,36
41