Avoiding false circuit breaker tripping
At the following link you can find information in the Internet on the topic of "Influence of high-
frequency currents on thermal overload trips of circuit breakers (3RV, 3VU) and overload
relays (3RU, 3UA)" and "Additional effects that can result in false trips".
FAQ entry ID: 24153083
http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&objid=24153083&no
deid0=20358027&caller=view&lang=de&extranet=standard&viewreg=WW&u=NDAwMDAxN
wAA&siteID=cseus
8.3.10

Signal connection

Risk of electric shock if the temperature monitoring circuit is incorrectly connected
In the case of a fault, Temp-S and Temp-F circuits do not provide electrical separation with
respect to power circuits.
To connect Temp-S and Temp-F temperature monitoring circuits, use a TM120 or a
SME12x, for example. You therefore comply with the directives for electrical separation
according to EN 61800-5-1 (previously electrical separation according to EN 50178).
Correctly connecting temperature sensors
NOTICE
Motor destroyed as a result of overtemperature
The motor can be destroyed as a result of overtemperature if you do not correctly connect
the temperature sensors.
When connecting temperature sensor cables with open conductor ends, pay attention to
the correct assignment of conductor colors.
1FW6 external rotor built-in torque motors
Configuration Manual, 12/2020, A5E50516483B AA
WARNING
Electrical connection
8.3 System integration