Sample Configuration - Siemens SINAMICS S120 1PM6 Configuration Manual

Hollow-shaft motors for main spindle drives
Table of Contents

Advertisement

Configuring
2.3 Selecting and dimensioning induction motors
2.3.7

Sample configuration

Moment of inertia J of motor + load = 0.2 kgm
the drive to operate continuously in the periodic duty cycle shown in the diagram below.
Figure 2-4
32
Periodic duty cycle
, friction is negligible. The application requires
2
1PM6/1PM4 Hollow-Shaft Motors for Main Spindle Drives
Configuration Manual, PPMS, 04/2008, 6SN1197-0AD23-0BP0