Electrical Supply; Electrical Requirements; Electrical Connections - Graco ProMix PD2K Installation Manual

Electronic proportioner
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Electrical Supply

Improper wiring may cause electric shock or other
serious injury if work is not performed properly. All
electrical wiring must be completed by a qualified
electrician and comply with all local codes and
regulations.

Electrical Requirements

Enclose all cables routed in the spray booth and high
traffic areas in conduit to prevent damage from paint,
solvent, and traffic.
The unit operates with 90-250 VAC, 50/60 Hz input
power, with a maximum of 7 A current draw. The
power supply circuit must be protected with a 15 A
maximum circuit breaker.
• A power supply cord compatible to your local
power configuration is not included. Wire gauge
size must be 8-14 AWG.
• The input power access port is 22.4 mm (0.88
in.) in diameter. A strain relief is provided which
accepts a cord diameter of 0.157–0.354 in. (4–9
mm). If another cord size is used, a user-supplied,
appropriate size strain relief must be installed.
332457H

Electrical Connections

See
Electrical Schematics, page
1. Verify that electrical power at the main panel is
shut off. Open the Control Box cover.
2. Thread the electrical cord wires through the
strain relief (S).
3. Connect the wires (L, N, G) securely to the
corresponding terminals of the terminal block (T),
as shown.
4. Tighten the strain relief nut securely.
5. Close the Control Box. Restore power.
6. Follow instructions in
Wire Key
Wire
Description
L
Line Power
N
Neutral
G
Ground
Figure 21 Control Box Electrical Connection
Electrical Supply
41.
Grounding, page
38.
37