Solvent Meter Accessory; Light Tower Accessory; Electrostatic Air Hose Quick Disconnect Kit; 24S004 - Graco ProMix PD2K Installation Manual

Electronic proportioner
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Solvent Meter Accessory

Solvent Meter Accessory
To install Solvent Meter Kit 280555, see manual
308778.
NOTE: Install the solvent meter downstream of the
solvent cutoff switch near the base unit.

Light Tower Accessory

To install Light Tower Kit 24K337, see manual
3A1906.
36
Electrostatic Air Hose
Quick Disconnect Kit

24S004

NOTE: To use a quick disconnect on an existing
electrostatic air hose, order Part No. 24S004 Kit. You
will also need to order Part No. 24U059 Electrostatic
Air Whip Hose (6 ft) [1.8 m].
Install the kit as follows.
1. Connect the quick disconnect (QD) to the existing
electrostatic air hose (P). The quick disconnect is
a 1/4 npsm(m) left-hand thread.
2. Screw the female end of adapter fitting (QF) onto
the quick disconnect (QD).
3. Screw the 24U059 Electrostatic Air Whip Hose
(WH) onto the male end of the adapter fitting
(QF).
NOTE: Make the following ground connections
to ensure air hose grounding continuity in the
electrostatic system.
4. Connect the ground wire (PG) of the existing
electrostatic air hose (P) to a true earth ground.
5. Connect the whip hose ground wire (WG) to
the green ground lug (GND) of the mix manifold
(M). Connect a ground wire (MG) from the mix
manifold ground lug to a true earth ground.
Figure 20 Electrostatic Air Hose Quick Disconnect Kit
332457H

Advertisement

Table of Contents
loading

Table of Contents