Download Print this page

Graco FIRE-BALL Series Instructions And Parts

Lubrication
Hide thumbs Also See for FIRE-BALL Series:

Advertisement

Quick Links

INSTRUCTIONS-PARTS LIST
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
INSTRUCTIONS
FIRE-BALLr and PRESIDENTr
LUBRICATION PUMPS
* For stationary or mobile installations
5:1 Ratio Fire-Ball Pump
900 psi (62 bar) MAXIMUM WORKING PRESSURE
Model No. Size
225094
16-gallon open drum
222086
16-gallon open drum, truck mounted
225642
55-gallon open drum
225640
55-gallon closed drum
206655
55-gallon closed drum, truck mounted
204264
55-gallon closed drum, truck mounted
225931
275-gallon obround tank
10:1 Ratio President Pump
1800 psi (120 bar) MAXIMUM WORKING PRESSURE
Model No. Size
225782
55-gallon open drum
225786
55-gallon closed drum
206656
55-gallon closed drum, truck mounted
222067
55-gallon closed drum, truck mounted
Warnings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fire-Ball Parts Lists and Drawings
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
Type*
S
M
S
S
M
M
S
Type*
S
S
M
M
Table of Contents
2
4
10
. . . . . . . . . . . . . . .
12
ECOPYRIGHT 1992, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
Hose
Cover
Bung
Kit
Adapter
X
X
X
X
X
X
X
X
X
X
X
Hose
Cover
Bung
Kit
Adapter
X
X
X
X
X
X
President Parts Lists and Drawings
Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Phone Number
. . . . . . . . . . . . . . . . . . . . . . . . . .
307883
Rev. F
Sturdi
Hold-
Clamp
Down Kit
X
X
X
X
X
X
X
Sturdi
Hold-
Clamp
Down Kit
X
X
X
X
X
. . . . . . . . . . . . . .
14
16
16

Advertisement

loading

Summary of Contents for Graco FIRE-BALL Series

  • Page 1 Fire-Ball Parts Lists and Drawings ....GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 ECOPYRIGHT 1992, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
  • Page 3 WARNING WARNING INJECTION HAZARD Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin may look like just a cut, but it is a serious injury.
  • Page 4 WARNING WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment. Refer to Grounding below. D If there is any static sparking or you feel an electric shock while using this equipment, stop dispensing immediately.
  • Page 5 Notes 307883...
  • Page 6 Installation–Stationary Mounting The typical installation shown in Fig. 2 is only an installation guide; it is not an actual system design. Contact your Graco distributor for assistance in designing a system to suit your needs. For Stationary Mountings A Fluid outlet line...
  • Page 7 Installation–Stationary Mounting D Install a thermal relief kit on the dispensing valve WARNING side of the pump to assist in relieving pressure in the pump, hose, and dispensing valve due to heat A bleed-type master air valve is required in the expansion.
  • Page 8 Installation–Mobile Mounting The typical installation shown in Fig. 4 is only an installation guide; it is not an actual system design. Contact your Graco distributor for assistance in designing a system to suit your needs. For Mobile Mountings See Air and Fluid...
  • Page 9 Installation–Mobile Mounting Closed Bung-Type-Drum, Cover-Mounted Pump 1. Insert the pump riser tube through the gasket (W) and drum cover (X). Fasten the Fire-Ball pump from the top side and the President pump from the bottom side. See Fig. 6. 2. Slide the rubber grommet (Y), tapered end down, W Gasket onto the riser tube and push it up against the pump X Drum cover...
  • Page 10 Operation Pressure Relief Procedure 3. For the pump that is connected, trigger the dispensing valve into a grounded metal waste WARNING container, making firm metal-to-metal contact between the container and valve. Open the INJECTION HAZARD bleed-type master air valve and open the pump air To reduce the risk of serious bodily regulator slowly, just until the pump is running.
  • Page 11 Notes 307883...
  • Page 12 Fire-Ball Parts Lists and Drawings Model 222063 Hose Kit for Fire-Ball Pump Part No. Description Qty. 203320 AIR HOSE, 3/8” ID, cpld 3/8–14 npt (mbe), 72” (1.8 m) 220591 FLUID HOSE, 1/2” ID, cpld 1/2–14 npt(mbe), 72” (1.8 m) 155494 UNION, 90_, 3/8–14 npt(m) x 3/8 npsm(f) swivel 155470...
  • Page 13 Fire-Ball Parts Lists and Drawings Model 206655 5:1 Ratio Fire-Ball, 55-Gallon Closed Drum Part No. Description Qty. 203857 5:1 FIRE-BALL PUMP See manual 306518 for parts. 222063 HOSE & FITTING KIT See parts on page 12. 207367 DRUM COVER 222361 HOLD-DOWN KIT See manual 306345 for parts.
  • Page 14 President Parts Lists and Drawings Model 222066 Hose Kit for President Pumps Part No. Description Qty. 205418 AIR HOSE, 1/2 ID, cpld 1/2–14 npt (mbe), 72” (1.8 m) 109105 FLUID HOSE, 3/4” ID, cpld 3/4–14 npt(mbe), 72” (1.8 m) 155470 UNION, 90_, 1/2–14 npt(m) x 1/2 npsm(f) swivel 160327...
  • Page 15 Notes 307883...
  • Page 16 Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written...

This manual is also suitable for:

President series