This Unit Is Equipped With Adjustable Air Shutters (2).
The air shutters may be adjusted externally while unit is burning.
The unit is sent out with the recommended setting, but may need
to be fine tuned by installer.
NOTE: Fireplace must be turned off and cool to the touch before
proceeding.
1. Remove barrier screen and glass door. See maintenance and
service section of this manual. See Figure 53.
2. Loosen screws (2) that lock the air shutter handles.
See Figure 54.
Loosen (2) air shutter handle screws
Page 30

AIR SHUTTER ADJUSTMENT

Figure 53
Figure 54
3. Replace glass door. See maintenance and service section of
this manual.
4. Turn unit on, see operating instructions in home owner's
instructions, allow unit to warm up from 15-30 minutes to obtain
it's full flame appearance.
5. You may now adjust the air shutters. The right air shutter handle
adjusts the front air shutter and the left air shutter handle adjusts
the rear air shutter. Slide the air shutter handle towards the right
to open and to the left to close. See Figure 55.
Rear
Close
6. Turn off unit and allow to cool before replacing the barrier screen.
See maintenance and service section of this manual.
Front
Open
Figure 55