Horizontal Termination - Empire Comfort Systems DVCT40CSP95N-1 Installation Instructions Manual

Direct-vent zero clearance gas fireplace heater
Hide thumbs Also See for DVCT40CSP95N-1:
Table of Contents

Advertisement

One 90° Elbow
B
A
TO BOTTOM
OF UNIT
EXAMPLE VENT RUNS
Initial Pipe Length
(In Inches)
24
36
48
NOTE: Pipe straps must be used every 2 feet to secure venting.
Two 45° Elbows
Installation requirements to replace the first 90° elbow with two
45° elbows:
A
EXAMPLE VENT RUNS
Initial Pipe Length
(In Inches)
24
36
48
GENERIC MODEL SHOWN
Page 26

HORIZONTAL TERMINATION

INSTALLED
VERTICALLY
2'
MINIMUM
A-Vertical
B-Horizontal
(In Feet)
(In Feet)
6
6
7
9
8
12
Figure 41
B
A-Vertical
B-Horizontal
(In Feet)
(In Feet)
7
9
8
12
9
15
Figure 42
Two 90° Elbows
NOTE: Subtract 3 feet from the total horizontal measurement for
each 90° elbow installed horizontally. Subtract 1-1/2 feet from the
total horizontal measurement for each 45° elbow installed hori-
zontally.
B
EXAMPLE VENT RUNS
Initial Pipe Length
(In Inches)
24
36
48
Three 90° Elbows
A
TO BOTTOM
OF UNIT
B
EXAMPLE VENT RUNS
Initial Pipe Length
(In Inches)
24
36
48
GENERIC MODEL SHOWN
INSTALLED
HORIZONTALLY
A
A-Vertical
B-Horizontal
(In Feet)
(In Feet)
6
3
7
6
8
9
Figure 43
INSTALLED
VERTICALLY
INSTALLED
VERTICALLY
A-Vertical
B-Horizontal
(In Feet)
(In Feet)
6
6
7
9
8
12
Figure 44
40651-2-0320
2'
MININUM
2'
MININUM