DIMENSIONS (In Inches)
Unit Only
A1
59
A2
59
B
57-3/4
C
23-1/2
Page 16

INSTALLATION

A1
With Outdoor Kit
59
62
58
25-1/2
Figure 16
The fireplace can be mounted on any of the following surfaces:
1.
A flat, hard combustible or non-combustible surface.
2.
A raised wooden platform.
3.
Four corner supports. (Example: Four concrete masonry
blocks.) These supports must be positioned so they contact
all four perimeter edges on the bottom of the fireplace, if
allowed by local codes.
NOTICE: Verify the gas supply and electrical considerations
before beginning the framing.
Framing Information
Fireplace framing can be built before or after the fireplace is set
in place. Position framing to accommodate wall covering and
fireplace facing material. Construct the fireplace framing with
2 x 4 lumber or heavier. If outdoor kit is installed, header
must be metal studs. Refer to the INSTALLATION TABLE for
A2
minimum framing dimensions.
Before construction begins, measure fireplace dimensions
and verify framing methods and wall covering details.
CAUTION
40651-2-0320