III. e - CORD & PLUG:
All Traulsen Blast Chill models (except model RBC100
which is supplied with a cord set but no plug) are sup-
plied with a cord & plug attached. It is shipped coiled
at the top of the cabinet, secured by a nylon strip. For
your safety and protection, all units supplied with a
cord and plug include a special three-prong ground-
ing plug on the service cord. Select only a certified
electrical outlet with grounding plug for power source.
NOTE: Do not under any circumstances, cut or remove
the round grounding prong from the plug, or use an
extension cord.
III. f - ELECTRICAL REQUIREMENTS:
Model RBC50 is normally provided with two (2) ground-
ing type cords with plugs (NEMA 5-15P). Two (2) sepa-
rate 115/60/1 volt, 20 amp, grounded circuits with re-
ceptacle must be provided by a certified electrician to
assure proper operation of the equipment.
Model RBC100 is normally provided with a grounding
type cord without a plug. A 220/60/1 volt, 4 wire, 20
amp grounded circuit with receptacle should be pro-
vided by a certified electrician to assure that the com-
puterized control is not adversely affected by the op-
eration of other equipment.
Models RBC200 and RBC200RT are normally provided
with a grounded cordset (NEMA 5-20P). A separate
115/60/1 volt, 20 amp, grounded circuit should be pro-
vided by a certified electrician to assure that the com-
puterized control is not adversely affected by the op-
eration of other equipment.
Models RBC400 and RBC400RT are normally provided
with two (2) grounded cordsets (NEMA 5-20P). Two (2)
separate 115/60/1 volt, 20 amp, grounded circuits
should be provided by a certified electrician to assure
that the computerized control is not adversely affected
by the operation of other equipment.
III. g - PROPER CLEARANCES:
Model RBC50: Make certain that there are no obstruc-
tions in front of the louver panels on the left and right
front sides of the unit. This will allow for sufficient air
flow to the refrigeration system and maintenance ac-
cess.
Model RBC100: A minimum of 4" clearance on the right
side, 6" on the left side and 6" clearance in the rear
(see figure 3). This will allow for sufficient air flow to
the refrigeration system and maintenance access.
Models RBC200, RBC200RT, RBC400 & RBC400RT:
Insure an overhead clearance of 12" and a rear clear-
ance of 4"(see figure 4). This will allow for sufficient
air flow to the refrigeration system and maintenance
access.
III. INSTALLATION (continued)
Air
Intake
4" Clearance
In Rear
-3-
6" Clearance
In Rear
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
6"
Fig. 3
Fig. 4
4"
12" Clearance
On Top
4" Clearance On Right
Side For Drain Tube