5
4. [X-3212 Servo Test (3-0)]: Focus Close 2 state screen
Note) Value of the data will change upon execution of the command.
Operation cannot be made until completion of displaying the value from T. Bal to OFF TRACK.
[1]
Succeed to Tracking Close state.
[2]
Execution and stop of CRG+
[3]
Execution and stop of CRG-
[4]
Succeed to RF Level display state.
[OK]
Execution/stop
[BACK] 1, [X-3212 Servo Test]: Return to Power Off state screen.
5. [X-3212 Servo Test (4-0)]: Tracking Close state screen
Note) Value of the data will change upon execution of the command.
Operation cannot be made until completion of displaying the value from F. Bal(0) to AS Normal(1).
[1]
Error Rate display (Operation cannot be made for approximately 10 seconds after execution.)
[2]
Read speed change (Fixed speed for CD.)
[3]
Go to Track Jump + screen.
[4]
Go to Track Jump – screen.
[5]
Execution of Focus Jump
[6]
Go to ID Search screen.
[7]
3, [x-3212 Servo Test (2-0):] Succeed to Focus Close 1 state screen
[OK]
Execution/stop
[BACK] 1, [X-3212 Servo Test]: Return to Power Off state screen.
5
6
AVIC-D3/XU/UC
6
7
7
8
A
B
C
D
E
F
237