- CALIBRATION
Outline
A
Press "+" cursors on the screen one by one for calibration, and the setting values are saved in the EEPROM.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
1
+ 13
2
3
+ 14
4
5
+ 15
6
B
7
+ 16
8
9
*) The numbers above indicate the order of the cursors being displayed.
Operational specifications
Press the cursors displayed at 16 locations on the screen one by one for calibration, and the process will be
completed by pressing the last cursor (total 17 locations).
After the 17th location has been displayed, "FINISHED" will be displayed in the center of the screen. After 2
C
seconds, the screen will return to the top MENU.
The cursor is displayed only one at a time, and the next cursor will be displayed when the previous one has been
pressed correctly.
If the SOURCE key is pressed before pressing 17 locations, NG will be displayed, and after 2 seconds, the screen
will return to the top MENU.
Details of the process
When the 17th location is pressed, the setting values and normal ending information are saved in the EEPROM,
and "FINISHED" will be displayed.
If the SOURCE key is pressed during the process and the inspection is finished, the EEPROM will save the NG
ending information, and "NG" is displayed.
D
E