Storing A Device - Siemens SINAMICS SM150 Operating Instructions Manual

Medium-voltage drive
Table of Contents

Advertisement

NOTICE
Damage caused by excessively high blow-out pressure
If the blow-out pressure used exceeds 6 bar, the piping and the heat sink can become
damaged.
● Do not exceed the blowout pressure of 6 bar. Avoid pressure surges.
4.5.2

Storing a device

If you are not going to commission the device immediately after delivery, ensure that it is stored
correctly.
Preconditions and preparations
● Store goods only in undamaged packaging. Unpack the goods if the packaging is damaged.
● Repair any damage to the packaging before putting the equipment into storage insofar as
General instructions for storage
Wherever possible, store the device in a storage room. The place of storage must satisfy the
following general conditions:
● Select a sufficiently sized dry and horizontal place of storage that is above flood level and
● The place of storage must be well ventilated as well as free of dust and frost.
● Protect the device against shocks and humidity.
SINAMICS SM150 6SL3845-7NN42-2AA3 HBIS Shigang WRM NTM
Operating Instructions Rev.202003051222 3005356504
Correctly store the goods corresponding to the type of goods.
this is necessary to ensure proper storage conditions.
free of vibration (v
≤ 0.2 mm/s).
eff
– Provide protection against extreme weather conditions.
– Optimum temperatures are between 10° C (50° F) to 50° C (120° F).
– Room temperature should be approx. 10 °C (14 °F) above the outside temperature.
– The temperature may not fall below ‑20 °C (-4 °F).
– For lower temperatures, agree on suitable measures together with Siemens.
– Relative humidity should be less than 60%.
– The floor of the place of storage must be sufficiently strong. Do not exceed maximum
permissible floor load levels or storage compartment load levels.
– The ambient air must not contain any harmful gases.
Preparations for use
4.5 Storage
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents