Siemens SIMATIC ET 200SP Manual page 33

Communication module io-link master cm 4xio-link (6es7137-6bd00-0ba0)
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Article number
Power loss
Power loss, typ.
Digital outputs
Cable length
unshielded, max.
IO-Link
Number of ports
of which simultaneously controllable
IO-Link protocol 1.0
IO-Link protocol 1.1
Transmission rate
Cycle time, min.
Size of process data, input per port
Size of process data, input per module
Size of process data, output per port
Size of process data, output per module
Memory size for device parameter
Master backup
Configuration without S7-PCT
Cable length unshielded, max.
Operating modes
IO-Link
DI
DQ
Time Based IO
TIO IO-Link IN
TIO IO-Link OUT
TIO IO-Link IN/OUT
Connection of IO-Link devices
Port type A
Port type B
via three-wire connection
Isochronous mode
Isochronous operation
(application synchronized up to terminal)
Communication module IO-Link Master CM 4xIO-Link (6ES7137-6BD00-0BA0)
Manual, 10/2017, A5E03856846-AD
6ES7137-6BD00-0BA0
1 W
20 m; Also applies for shielded cables
4
4
Yes
Yes
4.8 kBaud (COM1); 38.4 kBaud (COM2),
230.4 kBaud (COM3)
2 ms; dynamic, depending on user data length
32 byte; max.
144 byte; max.
32 byte; max.
128 byte; max.
2 kbyte; for each port
Yes
Yes
20 m
Yes
Yes
Yes; max. 100 mA per channel
No; Only for PROFINET and configuration as
version with FW V2.0 or V2.1
No; Only for PROFINET and configuration as
version with FW V2.0 or V2.1
No; Only for PROFINET and configuration as
version with FW V2.0 or V2.1
Yes
Yes; 24 V DC via external terminal
Yes
No; Only for PROFINET and configuration as
version with FW V2.0 or V2.1
Technical specifications