  • Page 2 ___________________ Preface ___________________ Documentation guide ___________________ SIMATIC Product overview ___________________ Connecting ET 200SP DQ 16x24VDC/0.5A BA ___________________ Parameters/address space digital output module (6ES7132-6BH00-0AA0) ___________________ Interrupts/diagnostic alarms Manual ___________________ Technical specifications ___________________ Parameter data record 02/2018 A5E42404662-AA...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Purpose of the documentation This manual supplements the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). Functions that generally relate to the system are described in this manual. The information provided in this manual and in the system/function manuals supports you in commissioning the system.
  • Page 5 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 6: Table Of Contents

    Table of contents Preface ..............................3 Documentation guide ..........................6 Product overview ..........................10 Properties ..........................10 Connecting ............................12 Wiring and block diagram ....................... 12 Parameters/address space ........................15 Parameters ..........................15 Declaration of parameters ...................... 17 Address space ........................18 Interrupts/diagnostic alarms ........................
  • Page 7: Documentation Guide

    Documentation guide The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Basic information The system manual describes in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP.
  • Page 8 You can download the product information free of charge from the Internet (https://support.industry.siemens.com/cs/us/en/view/73021864). Manual Collection ET 200SP The Manual Collection contains the complete documentation on the SIMATIC ET 200SP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (http://support.automation.siemens.com/WW/view/en/84133942).
  • Page 9 Solutions are shown in interplay with multiple components in the system - separated from the focus in individual products. You can find the application examples on the Internet (https://support.industry.siemens.com/sc/ww/en/sc/2054). TIA Selection Tool With the TIA Selection Tool, you can select, configure and order devices for Totally Integrated Automation (TIA).
  • Page 10 Documentation guide PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network during commissioning. PRONETA features two core functions: ● The topology overview independently scans PROFINET and all connected components. ● The IO check is a fast test of the wiring and the module configuration of a system.
  • Page 11: Product Overview

    Product overview Properties Article number 6ES7132-6BH00-0AA0 View of the module ① ⑦ Module type and name Function class ② ⑧ LED for diagnostics Color coding module type ③ ⑨ 2D matrix code Function and firmware version ④ ⑩ Wiring diagram Color code for selecting the color identification labels ⑤...
  • Page 12 ● Color identification labels ● Reference identification label ● Shield connector See also You can find additional information on the accessories in the system manualET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). DQ 16x24VDC/0.5A BA digital output module (6ES7132-6BH00-0AA0) Manual, 02/2018, A5E42404662-AA...
  • Page 13: Connecting

    You can find information on wiring the BaseUnit as well as information on wiring your system with potential distribution modules in the system manual Distributed I/O System ET 200SP (https://support.industry.siemens.com/cs/ww/en/view/58649293). Note The load group of the module must begin with a light-colored BaseUnit. Keep this in mind also during the configuration.
  • Page 14 Connecting 3.1 Wiring and block diagram Wiring: 1-wire connection of actuators The following figure shows the block diagram and an example for the terminal assignment of the digital output module DQ 16×24VDC/0.5A BA on the BaseUnit BU type A0 (1-wire connection).
  • Page 15 Connecting 3.1 Wiring and block diagram Example: 2-wire connection of actuators with potential distribution module The following figure shows an example for the terminal assignment of the digital output module DQ 16×24VDC/0.5A BA on the BaseUnit BU type A0 (2-wire connection) in combination with a potential distribution module.
  • Page 16: Parameters/Address Space

    Parameters/address space Parameters Parameters for DQ 16x24VDC/0.5A BA Specify the module properties with the various parameters in the course of your STEP 7 configuration. The following table lists the configurable parameters. The effective range of the configurable parameters depends on the type of configuration. The following configurations are possible: ●...
  • Page 17 Parameters/address space 4.1 Parameters The following parameter settings are possible: Table 4- 1 Configurable parameters and their defaults (GSD file) Parameters Range of values Default Parameter Scope with configuration software, e.g. reassignment STEP 7 (TIA Portal) in RUN GSD file GSD file PROFINET IO PROFIBUS DP...
  • Page 18: Declaration Of Parameters

    You take the potential of the self-assembling voltage buses P1, P2 and AUX from the left neighbor. A potential group ends with the dark-colored BaseUnit, which follows a light-colored BaseUnit or server module in the station configuration. See also ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) DQ 16x24VDC/0.5A BA digital output module (6ES7132-6BH00-0AA0) Manual, 02/2018, A5E42404662-AA...
  • Page 19: Address Space

    Parameters/address space 4.3 Address space Address space The module can be configured differently in STEP 7; see following table. Depending on the configuration, additional/different addresses are assigned in the process image output/input. Configuration options of DQ 16x24VDC/0.5A BA You can configure the module with STEP 7 (TIA Portal) or with a GSD file. If you configure the module by means of a GSD file, the configurations are available under various short designations/module names;...
  • Page 20: Interrupts/Diagnostic Alarms

    Interrupts/diagnostic alarms Status and error display LED display DQ 16x24VDC/0.5A BA ① DIAG (green/red) ② Channel status (green) ③ PWR (green) Figure 5-1 LED display Meaning of the LEDs The following tables contain the meaning of the status and error displays. Remedial measures for diagnostic alarms can be found in chapter Diagnostic messages (Page 21).
  • Page 21 Interrupts/diagnostic alarms 5.1 Status and error display DIAG LED Table 5- 1 DIAG LED fault display DIAG LED Meaning Backplane bus supply of the ET 200SP not OK Off
 Module not configured Flashing Module parameters assigned Module diagnostics is available Flashing LED channel status Table 5- 2...
  • Page 22: Interrupts

    Interrupts/diagnostic alarms 5.2 Interrupts Interrupts The DQ 16×24VDC/0.5A BA digital output module supports diagnostic interrupts. Diagnostic interrupts The module generates a diagnostic interrupt at the following events: ● Parameter assignment error ● Supply voltage missing Diagnostic messages A diagnostics alarm is generated and the DIAG-LED flashes on the module for each diagnostics event.
  • Page 23: Technical Specifications

    Technical specifications Technical specifications of the DQ 16×24VDC/0.5A BA Article number 6ES7132-6BH00-0AA0 General information Product type designation DQ 16x 24 V DC/0.5 A BA, PU 1 Firmware version V0.0 FW update possible • usable BaseUnits BU type A0 Color code for module-specific color identifica- CC00 tion plate Product function...
  • Page 24 Technical specifications Article number 6ES7132-6BH00-0AA0 Power loss Power loss, typ. Address area Address space per module 2 byte Outputs • Hardware configuration Automatic encoding Mechanical coding element • Selection of BaseUnit for connection variants BU type A0 1-wire connection • BU type A0 + Potential isolation module 2-wire connection •...
  • Page 25 Technical specifications Article number 6ES7132-6BH00-0AA0 Parallel switching of two outputs for uprating • for redundant control of a load • Switching frequency 100 Hz with resistive load, max. • 2 Hz with inductive load, max. • 10 Hz on lamp load, max. •...
  • Page 26 2 000 m Dimensions Width 15 mm Height 73 mm Depth 58 mm Weights Weight, approx. 30 g Dimension drawing See manual ET 200SP BaseUnits (http://support.automation.siemens.com/WW/view/en/58532597/133300) DQ 16x24VDC/0.5A BA digital output module (6ES7132-6BH00-0AA0) Manual, 02/2018, A5E42404662-AA...
  • Page 27: Parameter Data Record

    Parameter data record Parameter assignment and structure of parameter data record The data record of the module has an identical structure, regardless of whether you configure the module with PROFIBUS DP or PROFINET IO. With data record 128, you can reconfigure the module in your user program regardless of your programming.
  • Page 28 Parameter data record A.1 Parameter assignment and structure of parameter data record Structure of data record 128 Note Channel 0 includes the diagnostics enable for the entire module. Figure A-1 Structure of data record 128 Header information The figure below shows the structure of the header information. Figure A-2 Header information DQ 16x24VDC/0.5A BA digital output module (6ES7132-6BH00-0AA0)
  • Page 29 Parameter data record A.1 Parameter assignment and structure of parameter data record Parameters The figure below shows the structure of the parameters for channels 0 to 15. You enable a parameter by setting the corresponding bit to "1". Figure A-3 Structure byte x to x+1 for the channels 0 to 15 DQ 16x24VDC/0.5A BA digital output module (6ES7132-6BH00-0AA0) Manual, 02/2018, A5E42404662-AA...
  • Page 30 Parameter data record A.1 Parameter assignment and structure of parameter data record Error transferring the data record The module always checks all the values of the transferred data record. Only if all the values were transferred without errors does the module apply the values from the data record. The WRREC instruction for writing data records returns corresponding error codes when errors occur in the STATUS parameter.

This manual is also suitable for:

6es7132-6bh00-0aa0

Table of Contents