REP 9.7 Developer Material

Parts List on (Refer to
General Tools and Supplies
Tools and Supplies (EO)
Machine Consumables, Section 6.)
Switch off the Main Power Switch. Disconnect the Power Cord.
Removal
1.
Remove the Developer Module
(REP
Do not rotate the Developer Module in the vertical position. This may cause Developer Material
to get into the Toner Cartridge Clutch (located at the end of the Developer Module).
2.
Place the Developer Module on a drop cloth on the floor.
3.
(Figure 1): Remove the Sump Shield from the Developer Module.
8850/ 510DP
(NACO),
WARNING
9.5).
CAUTION
General
1
Remove the screws (2)
1
Remove the toner dust
trap)
Figure 1 Removing the Sump Shield from the Developer Module
NOTE: In the following step rotate the Developer Module away from the Magnetic Roll.
03/2003
4-71
2
Loosen the screws (2)
3
Remove the Top
Shield
4
5
Remove the Sump
Remove the Sump
Shield from under
Shield
the edge (full
length)
Repairs and Adjustments