5.
(Figure 3): Remove the Pressure Equalizer Tubes.
1
Remove the Grip
Ring
6.
Using a vacuum cleaner, clean the entire Developer Module, Magnetic Roll, and Pressure
Equalizer Tubes thoroughly.
Ensure that the entire length of the tube on the Developer Module is clear of any developer.
7.
Using a vacuum cleaner, clean the housing where the Pressure Equalizer Tubes attach.
8850/ 510DP
3
Remove the Pres-
sure Equalizer Tube
2
Remove the gears
(3)
Figure 3 Removing the Pressure Equalizer Tubes
CAUTION
4
Remove the screw
03/2003
4-73
5
Remove the
retainer
6
Remove the Pressure
Equalizer Tube