Power Light
Indicates power to the
Sets the maximum feed
Runs all motors atfull
speed for one minute
Status Light
to check operation.
Will be lit in either stove or
After two minutes the
room temp mode when
pointer is not within o f
minimum burn andthe
position band except after
blowers will alternate
normal shut down. Blinks
from high to low evey
*"
e , . L . w u - e u
u,
, "," . " . , * . , . .
AUTO
below.
MANUAL
IGNITOR
\
Indicates power to
/
distribution blower.
Indicates power to
combustion blower
Indicates power to th
feed motor.
minute to remind you
that you are stillin
"Test Modef1.
\
Innitor switch
-
Set to appropriate
Start-Up mode.
Distribution Blower speed
/adjustment
range.
L =low
H
=
high
Variable speed anywhere
between
L
and
H;
although as the stove
temp. goes up, so does the
L and H scale.
Indicates ignitor is on.
(
WARNING ) HIGH
v
Disconnect power before
Mode Selector
/
\
\pllows you to choose between
Temp dial
/
\
Dealer Diagnostic Port
koom Temp Mode, Stove Temp
Allows you to anjust the room temperature in Room Temp
For dealer maintenance
Mode, or OFF. Also allows you
Mode using the outer scale marked in degrees Fahrenheit.
only. Requires special DDM
to va y the distribution blower
It also allows you to adjust the stove temperature while in
monitor supplied to Harman
speed by turning the knob to
Stove Temp Mode using the inner scale marked from 1 to 7.
Dealers exclusivelv.
the high or low side of each
mode.
Status light error messages:
1 Blink: Indicates control board self diagnostic failure.
This requires a manual reset*.
2 Blinks: Indicates that the jumper (J2) on the rear of
the control board is not connected. Without this jumper
the unit will only burn at minimum rate.
3 Blinks: Indicates ESP (Exhaust Sensing Probe) fail-
ure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed. If
aRoom Sensing Probe is then installed, the status light
will automatically reset.
5 Blinks (In Igniter Auto. Mode Only): Indicates
that the unit has failed to light within the 36 minute start
cycle. To reset
-
Turn Mode Selector to "OFF", then
17
turn to either mode again.)
6 Blinks
:
Indicates that the control has calculated poor
or incomplete combustion occurring for more than 50
minutes.
A six blink status may be set if the stove is allowed to
run out ofpellets. To reset, turn mode selector to "OFF"
then back on to the desired mode. If the unit was not
out ofpellets, see Troubleshooting section for more de-
tails.
*
Manual reset- disconnect power cord for a few sec-
onds and reconnect. If error still occurs call your Dealer.
NOTICE: When power is given to the stove, the con-
trol board will blink a few times to indicate current ver-
sion of control board.
This should not be confused with
error messages.