Chapter 8 Specifications
8.8
NCT-82
Performance
a)
Dry contact input
b)
Dry contact input channel
c)
Contact closure interface
1)
Driving power supply
2)
Logic
d)
Communication port
e)
Output sentence
f)
Compass safety distance
1)
Standard
2)
Steering
Analog interface (option)
If the optional analog to digital conversion board CEF-60 is added.
a)
Analog signal Input channel
b)
Analog signal interface
1)
Voltage range
2)
Current range
c)
Communication port
d)
Output sentence
Environmental condition
a)
Operating temperature
b)
Temperature and humidity
c)
Vibration
d)
Protection class
General specification
a)
Power voltage
b)
Power consumption
c)
Size
d)
Mass
e)
Color
116

Digital Signal Converter (32CH)

Dry contact
Up to 32 channels
DC +12V
Normal Close / Normal open
Connect to the RCU
IEC61162-1
0.3m
0.2m
Up to 8 channels
±1V, ±5V, ±10V
±20mA
Connect to the RCU
(same port as dry contact signals)
IEC61162-1
XDR sentence - Transducer measurement
-15°C to +55°C (IEC60945 protected type)
+40°C, 93% (non condensing)
2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
IP22
AC 100 to 120V ±10%, 1-phase 50/60Hz (IEC60945)
AC 200 to 240V ±10%, 1-phase 50/60Hz (IEC60945)
20VA
300(w) x 130(d) x 230(h) mm
2.8kg
N7 semi-gloss