5.2

Manual Operating and Activation

It is not recommended to operate the EPIRB function inside a life raft or under a cover or canopy.
Do not tie the lanyard (mooring rope) to the ship in distress, as this will prevent the unit to
functioning if the ship sinks.
1. Remove the locking pin from bracket.
2. Remove the front cover.
3. Take out the capsule from the bracket.
4. Break the seal and pull the locking pin holding the switch.
5. Push and move switch to the left, to "ON" position. The LED indicator, located at the top of the
capsule, will start to flash, indicating that the EPIRB function is operating.
6. Tie the capsule lanyard to oneself or to the survival craft.
7. If possible keep the capsule in an open area, away from any metal objects (ship construction
etc.) that may limit the satellite coverage. This is especially important for the capsule, since it
needs good reception to obtain a GPS position.
[NOTE]
To stop transmission, take the capsule out of the water and move the switch to "READY"
position.
Chapter 5 About Float-free Capsule