Chapter 6 Maintenance and Inspection
Error
Error
code
type
223
WARNING
301 to
CAUTION
324
325 to
WARNING
348
349
WARNING
350 to
CAUTION
373
374 to
WARNING
389
390 to
CAUTION
399
400
CAUTION
401
CAUTION
402
CAUTION
98
Alert indication
ARB internal failure
Sensor reception
failure (Serial CH*)
*: 1 to 24
Serial port (CH*)
initialization failure
*: 1 to 24
Serial port function
initialization failure
Sensor reception
failure (LAN CH*)
*: 1 to 16
LAN port initialization
failure (No.*)
*: 1 to 16
Sensor reception
failure (DAU1-CH*)
*: 1 to 10
Sensor reception
failure (DAU1-DAU)
Sensor reception
failure (DAU1-ADC)
Sensor reception
failure (DAU1-GYRO)
Alert contents
The internal error of the
ARB is occurring.
The sensor data could
not receive.
The initialization of
sensor port failed.
The initialization of
sensor port function
failed.
The sensor data of the
LAN can't receive.
The initialization of the
LAN port failed.
The sensor data can't
receive from the DAU.
The DAU output data
can't receive.
The output data of
DAU's built-in analog
interface can't receive.
The output data of
DAU's built-in gyro
interface can't receive.
Actions to take
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
1) Check the cable.
2) Check the equipment that is
displayed.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
1) Check the cable.
2) Check the equipment that is
displayed.
Reboot the RCU.
1) Check the wiring between the
RCU and the DAU.
2) Check the wiring between the
DAU and the sensor.
3) Check the equipment that is
displayed.
1) Check the wiring between the
RCU and the DAU.
2) Check the DAU.
1) Check the wiring between the
RCU and the DAU.
2) Check the DAU.
1) Check the wiring between the
RCU and the DAU.
2) Check the DAU.