Chapter 6 Maintenance and Inspection
Error
Error
code
type
031
CAUTION
041
CAUTION
042
059
INFO
060
INFO
061
INFO
062
INFO
063 to
INFO
065
066
INFO
101
CAUTION
102
WARNING
96
Alert indication
Time synchronization
failure
OPU* communication
failure
*: 1, 2
Battery expiration date
Fixed capsule beacon
expiration date
Float-free capsule
battery expiration date
RCU fan expiration
date
FGU* fan expiration
date
*: 1 to 3
Float-free capsule HRU
expiration date
Fixed capsule short
store period
Fixed capsule
connection failure
Alert contents
The RCU can't receive
the ZDA sentence from
the GPS.
The RCU can't
communicate the OPU.
The expiration date of
RCU's built-in battery is
under 1 year.
The expiration date of
FPC's underwater
acoustic beacon is
under 1 year.
The expiration date of
FFC's built-in battery is
under 1 year.
The expiration date of
RCU's built-in fan is
under 1 year.
The expiration date of
FGU's built-in fan is
under 1 year.
The expiration date of
FFC'S hydrostatic
release unit is under 1
year.
The FPC's data
recording possible time
has decreased.
The RCU can't
communicate with the
FPC.
Actions to take
Check the GPS. If the GPS is
working normally, please contact our
head office, or a nearby branch or
local office to request servicing.
1) Check the cable.
2) Reboot the RCU.
It is necessary to replace the
underwater acoustic beacon. Please
contact our head office, or a nearby
branch or local office to request
servicing.
It is necessary to replace the
underwater acoustic beacon. Please
contact our head office, or a nearby
branch or local office to request
servicing.
It is necessary to replace the battery.
Please contact our head office, or a
nearby branch or local office to
request servicing.
It is necessary to replace the fan.
Please contact our head office, or a
nearby branch or local office to
request servicing.
It is necessary to replace the fan.
Please contact our head office, or a
nearby branch or local office to
request servicing.
It is necessary to replace the
hydrostatic release unit. Please
contact our head office, or a nearby
branch or local office to request
servicing.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few days.
1) Check the cable.
2) Reboot the RCU.