Supplementary system components and encoder system integration
9.2 DRIVE-CLiQ encoder
9.2.4
Installation
The installation surfaces and screws must be clean and free of grease.
Screw M4 - 8.8 with threadlocker (0.1 < thread friction coefficient < 0.16). Minimum screw-in
depth 6 mm. Please observe the hardening time for the threadlocker.
For a permitted surface pressure P
For replacement, recut thread M4 and use new screws with threadlocker.
Figure 9-24
Figure 9-25
Figure 9-26
334
G
Installation: Synchro flange
Installation with clamp straps
Installation: Clamp flange with axial screws
≤ 280 N/mm
, use a washer.
2
Manual, 06/2019, 6SL3097-5AL00-0BP1
AC Drive